eur5

Mod. EUR5 Super Dry

° Water meter single jet
° Dry dial
° Magnetically driven
° Direct reading by 5 numerical rolls
° Anti-fraud ring and with rotable dial 360°
° For cold water (30° C) and for hot water (90° C), diameters are 13 and 20 mm (1/2"- 3/4")
° Long lasting performances
° Risks of corrosion and sedimentation are excluded
° Manufactured with top class raw materials
° Metrological class B-H/A-V
° PN16

Omolog.
n° B 94 321.04 1/2” 30°C
n° B 95 321.05 3/4” 30°C
n° B 96 411.01 1/2” 90°C
n° B 99 411.02 3/4” 90°C

Download technical sheet [in Acrobat format]

   
Size
  mm
in.
13
1/2"
20
3/4"
Capacity (with 10 m of loss of head)
Qmax m3/h 3 5
Nominal flow
Qn m3/h 1,5 2,5
Accuracy limits ± 2% Qt
± 5% Qmin
l/h
l/h
120
30
200
50
Reading dial
min
max
l
m3
0,05
100.000
0,05
100.000
Max working pressure   bar 16 16
   
Dimensions and weights
sezione_eur5_8
Typical error curve of turbine meters
grafico_errore_1_eng
   
Size
  mm
in.
13
1/2"
13
1/2"
13
7/8"-3/4"
20
3/4"
L   mm 80 110 115 130
H
  mm 65 65 65 70
h
  mm 14 14 14 18
B
  mm 78 78 78 78
Weights with unions Kg 0,60 0,62 0,70 0,66